CDC Compliant - Meets CDC requirements for vaccine storage.
Display - Simultaneously shows high, low and current temperatures.
Data Retrieval - No Software Needed. Units can remain in use while downloading and analyzing data. Status indicators show low battery, memory full, USB data transfer and active alarm state. Recorded data (CSV file) can be transferred from thermometer to PC or Mac using a USB flash drive (not included). Each thermometer has a unique ID allowing multiple units to be used in the same location.
Temperature Range - From -50° to 70°C (-58°F to 158°F) and resolution of 0.01 and maintains an accuracy of ±0.25°C/±0.25°F.
Data Logging - Maintains most recent 525,600 temperature observations. Memory can be cleared on the unit after downloading data.
Logging Interval Range - 1 minute to 24 hours
Programmable Alarm - Units store up to 10 unique alarm events. Alarm tracking feature stores in memory each alarm event detailing when the alarm state occurred and when the unit returned back to within range. Alarm state indicators include visual LEDs, audio alerts and flashing LCD segments.
Alarm Increments - 0.1°
NIST Traceability - To assure accuracy an individually serial-numbered Traceable® Certificate is provided with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Power - Includes 2 AAA batteries
We are experiencing longer than normal lead times on this product. Please contact us for availability.
Triple Display - Simultaneously show high, low and current temperatures. Choose from Fahrenheit or Celsius display.
Sensors - Uses probe in glycol bottle. 10-foot micro-cable permits refrigerator doors to close on it.
Min/Max Log - Records (MIN) and (MAX) temperature along with time and date for min/max readings and high/low alarm alerts. Thermometer does not store readings.
Programmable Alarm - Alarm is programmable in 0.1° increments. Visual and audible signals continue even if temperature returns to non-alarm range for up to 12 hours.
NIST Certified - To assure accuracy an individually serial-numbered Traceable® Certificate is provided with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Temperature Range - From -50° to 70°C (-58° to 158°F) with a resolution of 0.01° and maintains an accuracy of ±0.30°C/±0.30°F.
CDC Compliant - Meets CDC requirements for vaccine storage.
Display - Simultaneously shows high, low and current temperatures.
Data Retrieval - No Software Needed. Units can remain in use while downloading and analyzing data. Status indicators show low battery, memory full, USB data transfer and active alarm state. Recorded data (CSV file) can be transferred from thermometer to PC or Mac using a USB flash drive (not included). Each thermometer has a unique ID allowing multiple units to be used in the same location.
Temperature Range - From -50° to 70°C (-58°F to 158°F) and resolution of 0.01 and maintains an accuracy of ±0.25°C/±0.25°F.
Data Logging - Maintains most recent 525,600 temperature observations. Memory can be cleared on the unit after downloading data.
Logging Interval Range - 1 minute to 24 hours
Programmable Alarm - Units store up to 10 unique alarm events. Alarm tracking feature stores in memory each alarm event detailing when the alarm state occurred and when the unit returned back to within range. Alarm state indicators include visual LEDs, audio alerts and flashing LCD segments.
Alarm Increments - 0.1°
NIST Traceability - To assure accuracy an individually serial-numbered Traceable® Certificate is provided with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Triple Display - Simultaneously show high, low and current temperatures. Choose from Fahrenheit or Celsius display.
Sensors - Uses 2 probes in glycol bottles. 10-foot micro-cable permits refrigerator doors to close on it.
Min/Max Log - Records (MIN) and (MAX) temperature along with time and date for min/max readings and high/low alarm alerts. Thermometer does not store readings.
Programmable Alarm - Alarm is programmable in 0.1° increments. Visual and audible signals continue even if temperature returns to non-alarm range for up to 12 hours.
NIST Certified - To assure accuracy an individually serial-numbered Traceable® Certificate is provided with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Temperature Range - From -50° to 70°C (-58° to 158°F) with a resolution of 0.01° and maintains an accuracy of ±0.30°C/±0.30°F.
Safe Transporting - Chemotherapy waste transport bag provides reliable protection for hazardous contents.
Leak-resistant Zip Closure - CYTA (Cytotoxic Agent) labeled bag features a safe, convenient, leak-resistant zip closure for secure handling of chemo waste during transport.
Triple Display - Traceable Hi-Accuracy Thermometer with Probe shows current temperature as well as the Min/Max temperatures. Choose Fahrenheit or Celsius display.
Mix/Max Display - Displays min/max temperatures for last 24 hours (for each hour) and last 7 days (for each day) or last 31 days (for each day). Time/date stamp key shows exact time and date for all minimum and maximum readings.
Temperature Range - From -100° to 70°C (-148° to 158°F ( resolution 0.01°, maintains an accuracy of ±0.1°C/±0.1°F.
Programmable Alarm - Alarm is programmable in 0.1° increments and signals when temperature rises above/falls below set points. Visual LED flashes and audible alarm sounds continuously even if temperature returns to non-alarm range.
NIST Traceability - An individually serial-numbered Certificate is provided. It indicates traceability to standards provided.
Triple Display - Simultaneously show high, low and current temperatures. Choose from Fahrenheit or Celsius display.
Sensors - Uses 2 air sensor probes. 10-foot micro-cable permits refrigerator doors to close on it.
Min/Max Log - Records (MIN) and (MAX) temperature along with time and date for min/max readings and high/low alarm alerts. Thermometer does not store readings.
Programmable Alarm - Alarm is programmable in 0.1° increments. Visual and audible signals continue even if temperature returns to non-alarm range for up to 12 hours.
NIST Certified - To assure accuracy an individually serial-numbered Traceable® Certificate is provided with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Temperature Range - From -50° to 70°C (-58° to 158°F) with a resolution of 0.01° and maintains an accuracy of ±0.30°C/±0.30°F.
Proper Use - To provide drug protection up to one year, these labels must be used with the Class A Small, Medium and Large Blisters.
Application - Labels must be applied individually; cannot be applied in strips. Use with most thermal printers.
No Interference - One-piece foil backed labels have adhesive only on the border of the label. No adhesive is applied over the medication cavity or lift-open tab.
Label Storage - Laser labels should be stored at 70° - 80°F and 50% relative humidity (±5%) away from heat sources and not exposed to direct sunlight. Labels should be stored in the room in which they will be printed at least 48 hours prior to printing.
Online Label Printing Solution - Sign up for HCL’s FREE Online Labeling Program by going to: GoHCLabels.com and enjoy the benefits of quick, convenient pharmacy label printing using your desktop printer! Ready-made templates for HCL’s extensive line of unit dose labels save time and improve efficiency.
Click on the Aging Study Icon below to view the 18 Month Accelerated Aging Study for HCL Unit Dose Labels.
Proper Use - To provide drug protection up to one year, these labels must be used with the Class A Small, Medium and Large Blisters.
Application - Thermal Transfer Strip Labels allow users to label an entire strip of eight blisters at once.
No Interference - One-piece foil backed labels have adhesive only on the border of the label. No adhesive is applied over the medication cavity or lift-open tab.
Label Storage - Laser labels should be stored at 70° - 80°F and 50% relative humidity (±5%) away from heat sources and not exposed to direct sunlight. Labels should be stored in the room in which they will be printed at least 48 hours prior to printing.
Online Label Printing Solution - Sign up for HCL’s FREE Online Labeling Program by going to: GoHCLabels.com and enjoy the benefits of quick, convenient pharmacy label printing using your desktop printer! Ready-made templates for HCL’s extensive line of unit dose labels save time and improve efficiency.
CDC Compliant - Meets CDC requirements for vaccine storage.
Data Logging - Thermometer logs 2 years in 1 minute to 24-hour logging intervals. Stores more than 1 million observations. When storage is full the unit will stop recording and does not overwrite data.
Display - Simultaneously shows high, low and current temperatures.
Data Retrieval - No Software Needed. Units can remain in use while downloading and analyzing data. Status indicators show low battery, memory full, USB data transfer and active alarm state. Recorded data (CSV file) can be transferred from thermometer to PC or Mac using a USB flash drive (not included). Each thermometer has a unique ID allowing multiple units to be used in the same location.
Temperature Range - From -50° to 70°C (-58°F to 158°F) and resolution of 0.01 and maintains an accuracy of ±0.25°C/±0.25°F.
Programmable Alarm - Units store up to 10 unique alarm events. Alarm tracking feature stores in memory each alarm event detailing when the alarm state occurred and when the unit returned back to within range. Alarm state indicators include visual LEDs, audio alerts and flashing LCD segments.
Alarm Increments - 0.1°
NIST Traceability - To assure accuracy an individually serial-numbered Traceable® Certificate is provided with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Power - Includes 2 AAA batteries
We are experiencing longer than normal lead times on this product. Please contact us for availability.
Triple Display - Simultaneously show high, low, current probe temperatures or room temperature. Choose from Fahrenheit or Celsius display.
Sensors- Uses a non-sealed sensor. 10' micro-cable permits refrigerator doors to close on it.
Min/Max Log - Records (MIN) and (MAX) temperature from the last time the user manually clears the memory to the current temperature. Thermometer does not store readings.
Programmable Alarm - Alarm is programmable in 1° increments. Visual and audible signals continue even if temperature returns to non-alarm range for up to 12 hours.
NIST Traceability - Individually serial-numbered Traceable® Certificate is included with each thermometer. Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Temperature Range - Reads air temperatures from -50° to 70°C (-58° to 158°F) and external probe reads range rom -50° to 70°C (-58° to 158°F) with a resolution of 0.1° and accuracy of ±0.1°C/±0.1°F.
Power - Includes 1 AA battery
We are experiencing longer than normal lead times on this product. Please contact us for availability.
Triple Display - Simultaneously show high, low, current probe temperatures or room temperature. Choose from Fahrenheit or Celsius display.
Sensors- Uses glycol bottles. 10' micro-cable permits refrigerator doors to close on it.
Min/Max Log - Records (MIN) and (MAX) temperature from the last time the user manually clears the memory to the current temperature. Thermometer does not store readings.
Programmable Alarm - Alarm is programmable in 1° increments. Visual and audible signals continue even if temperature returns to non-alarm range for up to 12 hours.
NIST Traceability - Individually serial-numbered Traceable® Certificate is included with each thermometer. Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Temperature Range - From -50° to 70°C (-58° to 158°F) with a resolution of 1° and maintains an accuracy of ±0.1°C/±0.1°F.
Triple Display - Simultaneously show high, low, current probe temperatures or room temperature. Choose from Fahrenheit or Celsius display.
Sensors - Uses glycol bottles. 10' micro-cable permits refrigerator doors to close on it.
Min/Max Log - Records (MIN) and (MAX) temperature from the last time the user manually clears the memory to the current temperature. Thermometer does not store readings.
Programmable Alarm - Alarm is programmable in 1° increments. Visual and audible signals continue even if temperature returns to non-alarm range for up to 12 hours.
NIST Traceability - Individually serial-numbered Traceable® Certificate is included with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Temperature Range - From -50° to 70°C (-58° to 158°F) ; resolution 1°. Maintains an accuracy of ±0.1°C/±0.1°F.
Triple Display - Simultaneously show high, low, current probe temperatures or room temperature. Choose from Fahrenheit or Celsius display.
Sensors- Uses glycol bottles. 10' micro-cable permits refrigerator doors to close on it.
Min/Max Log - Records (MIN) and (MAX) temperature from the last time the user manually clears the memory to the current temperature. Thermometer does not store readings.
Programmable Alarm - Alarm is programmable in 1° increments. Visual and audible signals continue even if temperature returns to non-alarm range for up to 12 hours.
NIST Traceability - Individually serial-numbered Traceable® Certificate is included with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Temperature Range - -50 to 70°C (-58 to 158°F); maintains an accuracy of ±0.5°C/±0.5°F.
Triple Display - Simultaneously show high, low, current probe temperatures or room temperature. Choose from Fahrenheit or Celsius display.
Sensors- Uses glycol bottles. 10' micro-cable permits refrigerator doors to close on it.
Min/Max Log - Records (MIN) and (MAX) temperature from the last time the user manually clears the memory to the current temperature. Thermometer does not store readings.
Programmable Alarm - Alarm is programmable in 1° increments. Visual and audible signals continue even if temperature returns to non-alarm range for up to 12 hours.
NIST Traceability - Individually serial-numbered Traceable® Certificate is included with each thermometer. Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Temperature Range - From -50° to 70°C (-58° to 158°F) with a resolution of 1° and maintains an accuracy of ±0.1°C/±0.1°F.
Greater Range and Accuracy - Easily improve the effectiveness of drug diversion programs. High-accuracy handheld device features a wide read range from 0.0 – 95.0% Brix and 1.3300 to 1.5600 refractive index to cover a broad number of solutions. Unit is calibrated to distilled water.
Powerful - Designed with a durable sapphire prism and stainless steel well for years of use. Prism delivers 2.5x more conductivity to temperature than a conventional glass prism for greater accuracy of the Automatic Temperature Compensation (ATC). Unit records the last 225 measurements.
One Device, Not Multiple - Measures up to 3 user-defined scales and has a digital screen with three-button operation that is easy to use.
Display - Continuously and simultaneously displays relative humidity and temperature in °F or °C.
Min/ Max Display - Minimum and maximum memories may be displayed or cleared at any time with the touch of a button.
Temperature Range - Temperature range is 0° to 50°C (32° to 122°F) and with a resolution of 1° and maintains an accuracy of ±0.1°C/±0.1°F. Humidity range is from 25 to 95%, resolution is 1% RH, and accuracy is ±2% RH mid-range to ±4% RH elsewhere.
Solid State Sensors - Fast-response solid-state sensors display changes in less than 30 seconds. Display is updated once per second.
NIST Certified - Includes individually serial-numbered Traceable® Certificate.
Recalibration is the customer's responsibility and annual recalibration is recommended.
Promotes Proper Handling - Reclosable slider bag with bright yellow background and easy-to-read bold black print states “CAUTION CHEMOTHERAPY/CYTOTOXIC MATERIAL AFTER USE DISPOSE OF IN ACCORDANCE WITH ESTABLISHED PROCEDURES” in English and Spanish. Pre-printed bag helps improve handling precautions and proper procedures when transporting, storing or disposing of items used in chemotherapy prep or administration. Also helps improve caregiver safety and compliance with USP <800>.
Secure Closure - Thick bag with closed zipper provides secure closure of chemo waste. Larger size has space for items such as soiled wipes and odd-shaped care items.
High-Quality Film Delivers Superior Results - Achieve outstanding print results for Talyst AutoPack® and McKesson PACMED™ medication packaging machines at an attractive price! Transparent polyethylene film with White coating and premium Black wax ribbon (#19046, sold separately) are designed for use at high speeds and low energy levels to deliver high print density and fine definition.
Durable - Clear/White Film is made of a higher quality material and is less prone to tearing during the filling process.
Compliant - FDA approved for pharmaceutical applications and meets regulatory compliance for print material used with medication packaging machines.
High-Quality Ribbon Delivers Superior Results - Achieve outstanding print results for Talyst AutoPack® and McKesson PACMED™ medication packaging machines at an attractive price! Premium Black wax printing ribbon is designed for use at high speeds and low energy levels to deliver high print density and fine definition.
Long Lasting - Higher quality ribbon is less prone to breakage and requires less machine downtime.
Designed for use with Clear/ White Film (#19045, sold separately).