CDC Compliant - Meets CDC requirements for vaccine storage.
Data Logging - Thermometer logs two years in one-minute to 24-hour logging intervals. Stores more than 1 million observations. When storage is full the unit will stop recording and does not overwrite data.
Display - Simultaneously shows high, low and current temperatures.
Data Retrieval - No Software Needed. Units can remain in use while downloading and analyzing data. Status indicators show low battery, memory full, USB data transfer and active alarm state. Recorded data (CSV file) can be transferred from thermometer to PC or Mac using a USB flash drive (not included). Each thermometer has a unique ID allowing multiple units to be used in the same location.
Temperature Range - From -50° to 70°C (-58°F to 158°F) and resolution of 0.01 and maintains an accuracy of ±0.25°C/±0.25°F.
Programmable Alarm - Units store up to 10 unique alarm events. Alarm tracking feature stores in memory each alarm event detailing when the alarm state occurred and when the unit returned back to within range. Alarm state indicators include visual LEDs, audio alerts and flashing LCD segments.
Alarm Increments - 0.1°
NIST Traceability - To assure accuracy an individually serial-numbered Traceable® Certificate is provided with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Power - Includes two AAA batteries
We are experiencing longer than normal lead times on this product. Please contact us for availability.
CDC Compliant - Meets CDC requirements for vaccine storage.
Display - Simultaneously shows high, low and current temperatures.
Data Retrieval - No Software Needed. Units can remain in use while downloading and analyzing data. Status indicators show low battery, memory full, USB data transfer and active alarm state. Recorded data (CSV file) can be transferred from thermometer to PC or Mac using a USB flash drive (not included). Each thermometer has a unique ID allowing multiple units to be used in the same location.
Temperature Range - From -50° to 70°C (-58°F to 158°F) and resolution of 0.01 and maintains an accuracy of ±0.25°C/±0.25°F.
Data Logging - Maintains most recent 525,600 temperature observations. Memory can be cleared on the unit after downloading data.
Logging Interval Range - 1 minute to 24 hours
Programmable Alarm - Units store up to 10 unique alarm events. Alarm tracking feature stores in memory each alarm event detailing when the alarm state occurred and when the unit returned back to within range. Alarm state indicators include visual LEDs, audio alerts and flashing LCD segments.
Alarm Increments - 0.1°
NIST Traceability - To assure accuracy an individually serial-numbered Traceable® Certificate is provided with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Power - Includes two AAA batteries
We are experiencing longer than normal lead times on this product. Please contact us for availability.
Display - High-contrast graphic LCD screen displays real-time readings, graph and current status of data. Unit offers on-screen menus which provide real-time analysis of data either as a summary that shows highest and lowest readings and alarm conditions or as a graph that updates as new data is added.
Temperature Range - Measures and stores more than 250,000 temperature readings at user-set intervals over a -30° to +80°C (-22° to 176°F) range. Maintains an accuracy of ±0.1°C/±0.2°F. Logging frequency is between 10 seconds and 12 hours.
Easy-to-Use Software - Using Windows control software (available as a free download at www.easylogusb.com), users can quickly set up the data logger and view downloaded data by connecting the device to the PC's USB port with the supplied cable.
Power - Includes two ½AA batteries
NIST not included: NIST Certificate is available at point of sale through our Resource Group (ext: 1252).
We are experiencing longer than normal lead times on this product. Please contact us for availability.
Data Logging - Mobile friendly, WiFi-enabled temperature monitor offers unlimited readings with user-selected logging rate from every minute up to every 30 minutes.
Monitors work with 2.4GHz Wi-Fi networks only.
Set-Up - Once connected to WiFi, the unit can be added to the Stat Temp website and the sensor will show up on the user portal when plugged into the monitor.
Reports - Cloud-based storage allows instant access to reports for process, compliance or inspection.
No Fees - There is no subscription fee for Stat Temp.
No Limits - Users have unlimited cloud storage and can have any number of Stat Temp monitors linked to their portal.
Online Portals - Create portals on the Stat Temp website for locations; view all units being monitored or sort to show less or just by location.
Permissions - Set user-defined permissions based on shifts or roles.
Alerts - Configure real-time and user-defined alerts via text, email or phone call with forced acknowledgment of solutions. Example: Call Calvin, Fred and Cindy M-F, 8am-5pm; email Annie and text Tim M-F, 5pm-8am.
Power Source - Uses a pass-through plug that inserts into the same wall outlet as the cooling unit; no batteries to change out.
Loss of Power - Three-day battery backup
Min/Max Log - Provides min/max data for last 24 hours
CDC Compliant - Yes
Temperature Range - -50°C to 50°C (-58°F to 122°F)
Sensor Options - Includes one glycol sensor. Double sensor (21001) and room and air humidity sensor (21002) models also available.
NIST - Includes a four-year NIST certificate.
Includes - Monitor, sensor and free use of stat-temp.io
We are experiencing longer than normal lead times on this product. Please contact us for availability.
CDC Compliant - Meets CDC requirements for vaccine storage.
Data Logging - Thermometer logs 2 years in one-minute to 24-hour logging intervals. Stores more than 1 million observations. When storage is full the unit will stop recording and does not overwrite data.
Display - Simultaneously shows high, low and current temperatures.
Data Retrieval - No Software Needed. Units can remain in use while downloading and analyzing data. Status indicators show low battery, memory full, USB data transfer and active alarm state. Recorded data (CSV file) can be transferred from thermometer to PC or Mac using a USB flash drive (not included). Each thermometer has a unique ID allowing multiple units to be used in the same location.
Temperature Range - From -50° to 70°C (-58°F to 158°F) and resolution of 0.01 and maintains an accuracy of ±0.25°C/±0.25°F.
Programmable Alarm - Units store up to 10 unique alarm events. Alarm tracking feature stores in memory each alarm event detailing when the alarm state occurred and when the unit returned back to within range. Alarm state indicators include visual LEDs, audio alerts and flashing LCD segments.
Alarm Increments - 0.1°
NIST Traceability - To assure accuracy an individually serial-numbered Traceable® Certificate is provided with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Power - Includes two AAA batteries
We are experiencing longer than normal lead times on this product. Please contact us for availability.
CDC Compliant - Meets CDC requirements for vaccine storage.
Display - Simultaneously shows high, low and current temperatures.
Data Retrieval - No Software Needed. Units can remain in use while downloading and analyzing data. Status indicators show low battery, memory full, USB data transfer and active alarm state. Recorded data (CSV file) can be transferred from thermometer to PC or Mac using a USB flash drive (not included). Each thermometer has a unique ID allowing multiple units to be used in the same location.
Temperature Range - From -50° to 70°C (-58°F to 158°F) and resolution of 0.01 and maintains an accuracy of ±0.25°C/±0.25°F.
Data Logging - Maintains most recent 525,600 temperature observations. Memory can be cleared on the unit after downloading data.
Logging Interval Range - 1 minute to 24 hours
Programmable Alarm - Units store up to 10 unique alarm events. Alarm tracking feature stores in memory each alarm event detailing when the alarm state occurred and when the unit returned back to within range. Alarm state indicators include visual LEDs, audio alerts and flashing LCD segments.
Alarm Increments - 0.1°
NIST Traceability - To assure accuracy an individually serial-numbered Traceable® Certificate is provided with each thermometer.
Annual Recalibration is recommended. Recalibration is the customer's responsibility.
Power - Includes two AAA batteries
We are experiencing longer than normal lead times on this product. Please contact us for availability.
CDC Compliant – Meets CDC requirements for vaccine storage.
Display – Refrigerator and freezer logger features Hi/Low programmable alarms with visual status indicating green and red LED lights. LCD digital display screen with push button operation allows the user to cycle through the most recent, highest and lowest stored temperature readings.
Temperature Range - From -40° to 100°C (-40° to 212°F) probe measurement range with an accuracy of ±0.1°C/±0.2°F. Offers user set intervals with logging rates between 2 seconds and 1 hour. Glycol-filled bottle is on 3.0m cable and features an integrated magnet to attach logger to the storage unit.
Logging - Unit will measure and store 32,510 temperature readings before overwriting the oldest data when memory is full.
Easy-to-Use Software - Using Windows control software (available as a free download at www.easylogusb.com), users can quickly set up the data logger and view downloaded data by connecting the device to the PCs USB port.
NIST Traceability - An individually serial-numbered Certificate is provided. It indicates traceability to standards provided by NIST (National Institute of Standards and Technology).
Power - Includes one ½AA battery
We are experiencing longer than normal lead times on this product. Please contact us for availability.
Display - High-contrast LCD, with 2-1/2 digit temperature and humidity display function. The most recent logged value, maximum logged value and minimum logged value. In addition, logging and alarm status is shown using two high intensity LED's.
Temperature Range - From -35° to 80°C (-31° to 176°F). Maintains an accuracy of ±0.5°C/±1°F.
Programmable Alarms - Data logger stores up to 16,379 temperature readings at user set intervals. Also features high and low visual alarms.
Logging - Overwrites the oldest data when the memory is full.
NIST not included: NIST Certificate is available at point of sale through our Resource Group (ext: 1252).
Power - Includes one ½AA battery
We are experiencing longer than normal lead times on this product. Please contact us for availability.
Multi-Function Logger - Data logger stores up to 16,379 relative humidity and 16,379 temperature readings.
Display - High-contrast LCD, with 2-1/2 digit temperature and humidity display function. The most recent logged value, maximum logged value and minimum logged value can be displayed separately for humidity and temperature. In addition, logging and alarm status is shown using two high intensity LED's.
Temperature Range - From -35° to 80°C (-31° to 176°F) 0 to +100%RH measurement range. Features a high accuracy reading with overall accuracy ±0.55ºC (±1.04ºF) ±2.0%RH.
Programmable Alarms - The quoted long-term stability is < 0.5% RH/yr with an overall accuracy of +/- 3%. Also features high and low visual alarms.
Logging - Overwrites the oldest data when the memory is full.
NIST not included: NIST Certificate is available at point of sale through our Resource Group.
Temperature Range - -40ºC to 99ºC (-40ºF to 210ºF)
CDC Compliant - Meets CDC requirements for vaccine storage.
Info on Demand - Stores up to 16,000 real-time temperature readings. Sampling interval is configurable from 30 seconds to 18 hours. Reads current temperature and latest min/max at a glance, as well as display alarms for excursions.
Long Battery Life - Includes a fixed battery for one year of storage, two years of normal use.
Certified - Includes factory batch calibration certificate.
Easy Data Download - Can be connected to any computer with a USB port. Creates a comprehensive data file compatible with free LogTag® Analyzer operating software.
Reusable - Achieve an IP67 waterproof rating for vital vaccine monitoring devices and extend monitoring capability. Package includes 10 loggers and plastic sleeves that are reusable when used together.
No set-up required - One button press-to-start logging; press again to view LED temperature status.
Alarms - Pre-configured with appropriate sample rates and alarm thresholds:
20512 2 to 8ºC (36 to 46ºF)
20513 -20 to -16ºC (-4 to 3ºF)
Quick, Easy Download - USB connector plugs directly into a computer. Free EasyLog® CC software for Windows® allows users to download and graph data, then prime logger for next use.
Worry-Free Monitoring - Each logger offers 12 months of battery life.
Quantity - Two packs of five loggers and five plastic sleeves; 10 loggers total
We are experiencing longer than normal lead times on this product. Please contact us for availability.
Dimensions:
Dataloggers - 2⅜"W x 15⁄16"H
Pouch - 5"W x 2¾"H
Display - High-contrast graphic LCD screen displays real-time readings, graph and current status of data. Unit offers on-screen menus which provide real-time analysis of data either as a summary that shows highest and lowest readings and alarm conditions or as a graph that updates as new data is added.
Temperature Range - Measures and stores more than 250,000 temperature and humidity readings at user-set intervals over a -30° to +80°C (-22° to 176°F) range and 0 to 100% RH range at a resolution of 0.1°C and 0.1%RH. Maintains an accuracy of ±0.35°C/±0.59°F. Logging frequency is between 10 seconds and 12 hours.
Easy-to-Use Software - Using Windows control software (available as a free download at www.easylogusb.com), users can quickly set up the data logger and view downloaded data by connecting the device to the PC's USB port with the supplied cable.
Power - Includes two ½AA batteries
NIST not included: NIST Certificate is available at point of sale through our Resource Group (ext: 1252).
Data Logging - Mobile friendly, WiFi-enabled temperature monitor offers unlimited readings with user-selected logging rate from every minute up to every 30 minutes.
Monitors work with 2.4GHz Wi-Fi networks only.
Set-Up - Once connected to WiFi, the unit can be added to the Stat Temp website and the sensor will show up on the user portal when plugged into the monitor.
Reports - Cloud-based storage allows instant access to reports for process, compliance or inspection.
No Fees - There is no subscription fee for Stat Temp.
No Limits - Users have unlimited cloud storage and can have any number of Stat Temp monitors linked to their portal.
Online Portals - Create portals on the Stat Temp website for locations; view all units being monitored or sort to show less or just by location.
Permissions - Set user-defined permissions based on shifts or roles.
Alerts - Configure real-time and user-defined alerts via text, email or phone call with forced acknowledgment of solutions. Example: Call Calvin, Fred and Cindy M-F, 8am-5pm; email Annie and text Tim M-F, 5pm-8am.
Power Source - Uses a pass-through plug that inserts into the same wall outlet as the cooling unit; no batteries to change out.
Loss of Power - Three-day battery backup
Min/Max Log - Provides min/max data for last 24 hours
CDC Compliant - Yes
Temperature Range - -50°C to 50°C (-58°F to 122°F)
Sensor Options - Includes one room and air humidity sensor. two glycol sensors. Single sensor (21000) and (21002) models also available.
Includes - Monitor, sensor and free use of stat-temp.io
Reusable - Achieve an IP67 waterproof rating for vital vaccine monitoring devices and extend monitoring capability. Package includes 10 loggers and plastic sleeves that are reusable when used together.
No set-up required - One button press-to-start logging; press again to view LED temperature status.
Alarms - Pre-configured with appropriate sample rates and alarm thresholds:
20512 2 to 8ºC (36 to 46ºF)
20513 -20 to -16ºC (-4 to 3ºF)
Quick, Easy Download - USB connector plugs directly into a computer. Free EasyLog® CC software for Windows® allows users to download and graph data, then prime logger for next use.
Worry-Free Monitoring - Each logger offers 12 months of battery life.
Quantity - Two packs of five loggers and five plastic sleeves; 10 loggers total
Dimensions:
Dataloggers - 2⅜"W x 15⁄16"H
Pouch - 5"W x 2¾"H
Handles Extremes - Compatible with vaccines that require ultra-low temperatures. Includes USB data logger with LCD screen; buffer kit made of a bottle and crushed glass beads that will not freeze at extreme temperatures; and a stainless steel probe inserted into the buffer kit. Unit has a two-year battery life.
CDC Compliant - Meets CDC requirements for vaccine storage.
Temperature Range - -90ºC to 40ºC (-130ºF to 104ºF); measures and records up to 16,000 temperature recordings (enough for 67 days at 6-minute logging intervals).
At-a-Glance Readings - Displays current temperature and min/max as well as alarms triggered by excursions. Audible alarm and flashing red LED signals temperature breach. Alarm status remains visible for up to 30 days.
Data Download - Connect to a computer with a USB port and review data using free LogTag Analyzer.
NIST Calibration - Certificate is included; calibration term is two years.
Data Logging - Mobile friendly, WiFi-enabled temperature monitor offers unlimited readings with user-selected logging rate from every minute up to every 30 minutes.
Monitors work with 2.4GHz Wi-Fi networks only.
Set-Up - Once connected to WiFi, the unit can be added to the Stat Temp website and the sensor will show up on the user portal when plugged into the monitor.
Reports - Cloud-based storage allows instant access to reports for process, compliance or inspection.
No Fees - There is no subscription fee for Stat Temp.
No Limits - Users have unlimited cloud storage and can have any number of Stat Temp monitors linked to their portal.
Online Portals - Create portals on the Stat Temp website for locations; view all units being monitored or sort to show less or just by location.
Permissions - Set user-defined permissions based on shifts or roles.
Alerts - Configure real-time and user-defined alerts via text, email or phone call with forced acknowledgment of solutions. Example: Call Calvin, Fred and Cindy M-F, 8am-5pm; email Annie and text Tim M-F, 5pm-8am.
Power Source - Uses a pass-through plug that inserts into the same wall outlet as the cooling unit; no batteries to change out.
Loss of Power - Three-day battery backup
Min/Max Log - Provides min/max data for last 24 hours
CDC Compliant - Yes
Temperature Range - -50°C to 50°C (-58°F to 122°F)
Sensor Options - Includes two glycol sensors. Single sensor (21000) and room and air humidity sensor (21002) models also available.
NIST - Includes a four-year NIST certificate.
Includes - Monitor, two sensors and free use of stat-temp.io
We are experiencing longer than normal lead times on this product. Please contact us for availability.
Improve Accuracy - SureCheck™ technology allows users to set and monitor air temperature throughout incubation to determine that set points were met. User set intervals allow users to record temperatures as often as every 60 seconds. Use a flashdrive (not included) to download data points for easy record keeping.
Dual-Convection Technology - Allows users to choose between Mechanical Convection Mode for exceptional temperature uniformity or Gravity Convection Mode for longer incubations where airborne contamination or drying of samples may be an issue.
Storage Options - Includes two shelves; can accommodate up to eight. Additional shelves available through our Resource Group.
30 Days at-a-Glance - Fridge-Tag 2L’s direct display feature requires no software to quickly review 30 day’s worth of data instantly. Check all relevant refrigerator temperature monitoring data at any time and discover temperature violations immediately. Compact measurement device will store up to 60 days of temperature data that can quickly be downloaded in an easy to use comprehensive reports.
Sensor - Monitors the temperature inside the unit to protect the integrity of temperature-sensitive drugs. Includes a removable external probe temperature sensor that allows the display unit to be positioned outside the refrigerator while the probe remains inside.
Temperature Range - From -10° to 55°C (-13°F to 122°F) operating temperature range. Maintains an accuracy of ±0.5°C/±0.9°F. Measurement frequency is every minute.
Alarm - Fridge-Tag® 2L refrigerator thermometer features preset alarms to warn of temperature violation:
Preset alarm for Refrigerator: 60 minutes above 8.0ºC (or 46.4ºF); 15 minutes below 2.0ºC (or 35.6ºF).
Visual alarms will alert to any temperature violation. Clear OK sign is visible if the alarm limit has not been violated during the previous 30 days.
ISO 17025 Certified - Certification included with each unit.
We are experiencing longer than normal lead times on this product. Please contact us for availability.
Warranty - 2 years parts and labor; 2 additional years on compressor parts only
CDC Compliant - Meets CDC requirements for vaccine storage.
Temperature Range - Operating range 1º to 10ºC (34° to 50°F); preset at 4ºC.
Construction - Features HFC-free refrigerant (R600a), foam insulation and packaging. Includes four adjustable wire shelves (two full/two half) and a swing door that is right hinged (not reversible). Door includes a magnetic door gasket for positive seal and integrated door handle.
Note - This unit must have a 4" clearance on all sides for adequate ventilation.
Secure - Each unit features a key lock with two keys.
Compatibility:
• Probe access ports for data loggers.
• Pyxis®, Omnicell® and AcuDose RX® compatible.
Alarm Features:
• Digital temperature display.
• Alarm validation (audible, visual and remote)
Manufactured by American Biotech
Due to potential delays associated with COVID-19, lead times are subject to change. Current lead times are running 10 - 12 weeks.
Warranty - 2 years parts and labor; 2 additional years on compressor parts only
CDC Compliant - Meets CDC requirements for vaccine storage.
Temperature Range - Operating range 1º to 10ºC (34° to 50°F)
Construction - Features HFC-free refrigerant (R600a), foam insulation and packaging. Includes three adjustable wire shelves (two full and one half shelf) and a swing door that is right hinged (not reversible). Door includes a magnetic door gasket for positive seal and integrated door handle.
Note - This unit must have a 4" clearance on all sides for adequate ventilation.
Secure - Each unit features a key lock with two keys.
Compatibility:
• Probe access ports for data loggers.
• Pyxis®, Omnicell® and AcuDose RX® compatible.
Alarm Features:
• Digital temperature display.
• Alarm validation (audible, visual and remote)
Manufactured by American Biotech
Due to potential delays associated with COVID-19, lead times are subject to change. Current lead times are running 10 - 12 weeks.
Warranty - 2 years parts and labor; 2 additional years on compressor parts only
CDC Compliant - Meets CDC requirements for vaccine storage.
Alarm Features:
• Audible, visual and remote temperature alarms.
Temperature Range - Adjustable operating range 2° to 8°C (36° to 46°F).
Special Features - Refrigerator is °F/°C switchable, includes a thermometer and three-year NIST calibration certificate.
Construction - Features HFC-free refrigerant (R600a) with foam insulation and packaging. Includes two adjustable wire shelves and a swing door that is right hinged (not reversible). Door includes a magnetic gasket for positive seal and integrated handle. Labeled power cord states: Warning! Do not unplug the appliance or circuit. Expensive vaccine in storage.
Note - This unit must have a 4" clearance on all sides for adequate ventilation.
Secure - Each unit features a key lock with two keys.
Compatibility:
• Probe access ports for data loggers.
• Pyxis®, Omnicell® and AcuDose RX® compatible.
Digital temperature display.
Manufactured by American Biotech
Due to potential delays associated with COVID-19, lead times are subject to change. Current lead times are running 10 - 12 weeks.
Warranty - 2 years parts and labor; 2 additional years on compressor parts only
CDC Compliant - Meets CDC requirements for vaccine storage.
Temperature Range - 2° to 8°C (36º to 46ºF)
Special Features - Includes a thermometer and three-year NIST calibration certificate.
Construction - Features HFC-free refrigerant (R600a), foam insulation and packaging. Includes three adjustable wire shelves (two full and one half shelf) and a swing door that is right hinged (not reversible). Door includes a magnetic door gasket for positive seal and integrated door handle. Labeled power cord states: Warning! Do not unplug the appliance or circuit. Expensive vaccine in storage.
Note - This unit must have a 4" clearance on all sides for adequate ventilation.
Secure - Each unit features a key lock with two keys.
Compatibility:
• Probe access ports for data loggers.
• Pyxis®, Omnicell® and AcuDose RX® compatible.
Alarm Features:
• Digital temperature display.
• Alarm validation (audible, visual and remote)
Manufactured by American Biotech
Due to potential delays associated with COVID-19, lead times are subject to change. Current lead times are running 10 - 12 weeks.
Warranty - 2 years parts and labor; 2 additional years on compressor parts only
CDC Compliant - Meets CDC requirements for vaccine storage.
Temperature Range - Adjustable operating temperature range 2° to 8°C (36º to 46ºF) and is °F/°C
Special Features - Refrigerator is °F/°C convertible, includes a thermometer and three-year NIST calibration certificate.
Construction - Stainless steel unit features HFC-free refrigerant (R600a), foam insulation and packaging. Includes three wire shelves (two adjustable/one fixed) and a swing door that is right hinged. Left hinged doors are available through our Resource Group (Ext: 1252). Door includes a magnetic door gasket for positive seal and integrated door handle. Labeled power cord states: Warning! Do not unplug the appliance or circuit. Expensive vaccine in storage.
Secure - Each unit features a key lock with two keys.
Compatibility:
• Probe access ports for data loggers.
• Pyxis®, Omnicell® and AcuDose RX® compatible.
Alarm Features:
• Digital temperature display.
• Alarm validation (audible, visual and remote)
Manufactured by American Biotech
Due to potential delays associated with COVID-19, lead times are subject to change. Current lead times are running 10 - 12 weeks.
Warranty - 2 years parts and labor; 2 additional years on compressor parts only
CDC Compliant - Meets CDC requirements for vaccine storage.
Temperature Range - Adjustable operating temperature range 2° to 8°C (36º to 46ºF)
Special Features - Refrigerator is °F/°C convertible, includes a thermometer and three-year NIST calibration certificate.
Construction - Features HFC-free refrigerant (R600a) with foam insulation and packaging. Includes four adjustable wire shelves (two full/two half) and a swing door that is right hinged (not reversible). Door includes a magnetic door gasket for positive seal and integrated door handle. Labeled power cord states: Warning! Do not unplug the appliance or circuit. Expensive vaccine in storage.
Note - This unit must have a 4" clearance on all sides for adequate ventilation.
Secure - Each unit features a key lock with two keys.
Compatibility:
• Probe access ports for data loggers.
• Pyxis®, Omnicell® and AcuDose RX® compatible.
Alarm Features:
• Digital temperature display.
• Alarm validation (audible, visual and remote)
Manufactured by American Biotech
Due to potential delays associated with COVID-19, lead times are subject to change. Current lead times are running 10 - 12 weeks.
Warranty - 2 years parts and labor; 2 additional years on compressor parts only
CDC Compliant - Meets CDC requirements for vaccine storage.
Temperature Range - Adjustable operating temperature range 2° to 8°C (36º to 46ºF)
Special Features - Refrigerator is °F/°C convertible, includes a thermometer and three-year NIST calibration certificate.
Construction - Features HFC-free refrigerant (R600a), foam insulation and packaging. Includes three wire shelves (two adjustable/one fixed) and a swing door that is right hinged. Left hinged doors are available through our Resource Group (Ext: 1252). Glass door includes a magnetic door gasket for positive seal and integrated door handle. Labeled power cord states: Warning! Do not unplug the appliance or circuit. Expensive vaccine in storage.
Secure - Each unit features a key lock with two keys.
Compatibility:
• Probe access ports for data loggers.
• Pyxis®, Omnicell® and AcuDose RX® compatible.
Alarm Features:
• Digital temperature display.
• Alarm validation (audible, visual and remote)
Manufactured by American Biotech
Due to potential delays associated with COVID-19, lead times are subject to change. Current lead times are running 10 - 12 weeks.
Warranty - 2 years parts and labor; 2 additional years on compressor parts only
CDC Compliant - Yes
Construction - HFC-free refrigerant (R600a), foam insulation and packaging. Includes two adjustable shelves, a bottom-footed shelf to allow air circulation and a swing door that is right hinged (not reversible). Door includes a magnetic door gasket for positive seal and integrated door handle. Manual defrost.
Special Features - Refrigerator is °F/°C convertible with three-year NIST calibration certificate and a label on the power cord stating: Warning! Do not unplug the appliance or circuit. Expensive vaccine in storage.
Note: This unit must have 4" clearance on all sides for adequate ventilation.
Secure - Features a key lock with two keys
Compatibility:
• Probe access port for data loggers.
• Pyxis®, Omnicell® and AcuDose RX® compatible.
Alarm Features:
• Digital temperature display.
• Alarm validation (audible, visual, and remote).
Temperature Range - Adjustable operating temperature range -15° to -25°C (5º to -13ºF).
Manufactured by American Biotech
Due to potential delays associated with COVID-19, lead times are subject to change. Current lead times are running 10 - 12 weeks.
Warranty - 2 years parts and labor; 2 additional years on compressor parts only
CDC Compliant - Meets CDC requirements for vaccine storage.
Construction - Features HFC-free refrigerant (R600a), foam insulation and packaging. Includes two fixed wire shelves and a swing door that is right hinged. Left hinged doors are available through our Resource Group (Ext: 1252). Door includes a magnetic door gasket for positive seal and integrated door handle. Manual defrost.
Special Features - Refrigerator is °F/°C convertible; includes one refrigerator/freezer freestanding thermometer with three-year NIST calibration certificate and a label on the power cord stating: Warning! Do not unplug the appliance or circuit. Expensive vaccine in storage.
Secure - Features key lock with two keys
Compatibility:
• Probe access ports for data loggers.
• Pyxis®, Omnicell® and AcuDose RX® compatible.
Alarm Features:
• Adjustable digital temperature display.
• Audible validation (audible, visual, and remote).
Temperature Range - Adjustable operating temperature range -15° to -25°C (5º to -13ºF).
Manufactured by American Biotech
Due to potential delays associated with COVID-19, lead times are subject to change. Current lead times are running 10 - 12 weeks.
Warranty - 2 years parts and labor; 2 additional years on compressor parts only
CDC Compliant - Meets CDC requirements for vaccine storage.
Construction - Features HFC-free refrigerant (R600a), foam insulation and packaging. Includes two fixed wire shelves and a swing door that is right hinged. Left hinged doors are available through our Resource Group (Ext: 1252). Door includes a magnetic door gasket for positive seal and integrated door handle. Manual defrost.
Special Features - Refrigerator is °F/°C convertible; includes one refrigerator/freezer freestanding thermometer with three-year NIST calibration certificate and a label on the power cord stating: Warning! Do not unplug the appliance or circuit. Expensive vaccine in storage.
Secure - Features a key lock with two keys
Compatibility:
• Probe access ports for data loggers.
• Pyxis®, Omnicell® and AcuDose RX® compatible.
Alarm Features:
• Adjustable digital temperature display.
• Audible validation (audible, visual, and remote).
Temperature Range - Adjustable operating temperature range -15° to -25°C (5º to -13ºF).
Manufactured by American Biotech
Due to potential delays associated with COVID-19, lead times are subject to change. Current lead times are running 10 - 12 weeks.
To track the output of the extemporaneous unit dose packaging process, HCL developed a Package Record Control Form, which allows for the recording of pharmacy/manufacturer lot numbers, units packaged, expiration dates, signature of the packager and the signature of the supervisor or the checking pharmacist.